EVALUATION
CATEGORIES

The following is the list of evaluation items that can be handled by our lab. We can also make proposals for evaluation content tailored to your needs.

  • *Samples to be measured are limited to products available on the market for safety reasons.
  • *In principle, we do not conduct tests on products that have been developed. Please understand that.
evaluation 01

Charge/Discharge Cycle Test

Contents
  • We perform the test continue repeating for the specified number of times, in the temperature/condition specified.
  • We can perform the test under the conditions and number of test cycles requested by the customer within the scope of the cell/pack specifications and testing equipment.
    However, we may not be able to meet the customer's request due to the laboratory's testing schedule.
evaluation 02

Charge/Discharge Testing

Contents
  • The test is conducted at the specified charging and discharging temperatures and conditions.
  • The voltage, current, capacity, sample temperature, etc. are measured and recorded during charging, discharging, and rest time.
  • Different temperatures can be specified for charging and discharging.
  • We can also conduct tests under your desired conditions within the scope of the cell/pack specifications and testing equipment.
evaluation 03

Cell impedance measurement

Contents
  • Internal resistance is measured by AC method (1KHz) under specified conditions.
  • Cell impedance measurement can also be performed before and after charge/discharge cycle tests, charge/discharge tests, etc.
evaluation 04

Surface temperature continuous measurement

Contents
  • During charge-discharge cycle test and charge-discharge test, the surface temperature of the sample is continuously measured. (It will be at fixed time intervals.)
evaluation 05

Static Electricity Test

Contents
  • Contact discharge and air discharge are applied to each terminal of a sample, such as a pack, at a specified voltage.
  • After the test is completed, the battery voltage is measured in the case of packs, and the resistance is measured in the case of ID terminals.
evaluation 06

Safety standard testing

Contents
  • AC/DC withstand voltage test and insulation resistance test are performed.
  • The AC withstand voltage test can apply up to 5kVAC, the DC withstand voltage test can apply up to 6kVDC, and the insulation resistance tester can apply 1.2kV.
evaluation 07

Supporting in analyzing the root cause of malfunction on your behalf

Contents
  • Visually check for abnormalities in batteries, circuit boards, etc.
  • We use a high-resolution infrared sensor camera and a digital microscope to estimate the location of defects.
  • We analyze the cause of the defective part through online communication with the customer.